ADLINK PCM-9112+ User Manual
Page 87
                                    Advertising
                                    
                                        
                                    
                                
                                 
Calibration
• 79
D/A CH2 calibration
1. Connect the DVM (+) to CN3 pin-32 (AO2) and the DVM (-) to
A.GND.
2. Write the Digital value 0x0FFF into the register at Base+14 address
3. Trim the variable resister VR4 to obtain a +5V reading on the DVM.
A calibration utility is included with the ADLINK CD, which is included with the 
product package. A detailed calibration procedure and description can be 
found in the utility. Users only need to run the software calibration utility and 
follow the procedures. 
Note: When you first receive the PCI-9112 card, calibration is NOT
necessary, the PCI-9112 has been fully calibrated before it is 
shopped. 
.