5.9 _9112_AD_Set_Range

@ Description

This function is used to set the A/D analog input range by means of
writing data to the A/D range control register. There are two factors that
will change the analog input range - Gain and Input type.

The Gain can be from 0.5, 1, 2, 4, and 8 .The input type can be either
Bipolar or Unipolar.

The initial gain value is '1‘ and input type is bipolar, which are pre-set by
the PCI-9112 hardware. The relationship between analog input voltage
range, gain and input mode are listed in the table below:

** this table is suitable for PCI-9112 card.

AD_INPUT

GAIN

Input type

(Bipolar or Unipolar)

Input Range

AD_B_5_V 1

Bipolar

±5V

AD_B_2_5_V 2

Bipolar

±2.5V

AD_B_1_25_V 4

Bipolar

±1.25V

AD_B_0_625_V

8 Bipolar

±0.625V

AD_U_10_V

1

Unipolar

0V ~ 10V

AD_U_5_V

2

Unipolar

0V ~ 5V

AD_U_2_5_V

4

Unipolar

0V ~ 2.5V

AD_U_1_25_V

8

Unipolar

0V ~ 1.25V

AD_B_10_V 0.5

Bipolar

±10V

@ Syntax

Visual C++ (Windows-95)

int W_9112_ AD_Set_Range (int card_number, int ad_range)

Visual Basic (Windows-95)

W_9112_AD_Set_Channel (ByVal card_number As Long, ByVal

ad_range As Long) As Long

C/C++ ( DOS)

int _9112_AD_Set_Range (int card_number, int ad_range )

@ Argument

card_number:

the card number of PCI-9112

ad_range: the programmable range of A/D conversion,

please refer the the above table for the possible
range values.

@ Return Code

ERR_NoError
ERR_BoardNoInit
ERR_AD_InvalidRange