Vout vref dan = − × 4096, 3 d/a conversion – ADLINK PCM-9112+ User Manual

Page 47

Advertising
background image

Operation Theory

39

4.3 D/A

Conversion

The operation of the D/A conversion is less complex than the A/D operation.
You only need to write digital values into the D/A data registers and the
corresponding voltage will be outputted to AO1 or AO2. Refer to section 3.3
for information about the D/A data registers. The mathematical relationship
between the Digital number DAn and the output voltage is formulated as
follows:

Vout

Vref

DAn

= −

×

4096

Where the Vref is the reference voltage, the Vout is the output voltage, and
the DAn is the Digital value in the D/A data registers.

Before performing the D/A conversion, users should take care with the D/A
reference voltage, which is set by JP3 and JP4. Please refer to section 2.8
for jumper settings. The reference voltage will affect the output voltage. If the
reference voltage is -5V, the D/A output scaling will be 0~5V. If the reference
voltage is -10V, the D/A output scaling will be 0~10V.

The PCI-9112 has two unipolar analog output channels. To make a D/A
output connection to the appropriate D/A output, please refer to Figure 4.3.

To D/A Output

D/A Converter

-

+

Ref In

-5 or -10

INT or Ext

Analog GND

Pin-30 ( AO0)

Pin-32 ( AO1)

Pin-14 ( A.GND)

Figure 4.3 Connection of Analog Output Connection

D/A Output