Power-up do setup/read register – ADLINK PCI-7442 User Manual

Page 54

Advertising
background image

42

Register Format

Power-up DO Setup/Read Register

When the system enters the power up status, PCI-7442 can enter
the initial procedure which sends out the default initial value to 64-
CH digital outputs. You can configure the power-up default DO val-
ues and store them in the flash memory. With this, the DO goes to
a definite status when the system turns on.

You can program the 64-CH power-up default DO values by
accessing the Power-up DO Setup Register in turn. After access-
ing the last Power-up DO Setup Register (BASE+0x92h), it could
take up to 0.5s to finish writing the procedure to the flash memory.
You may check if the procedure is finish or not by nAction_Ready
flag.

You can read the configured power-up initial DO values stored in
the flash memory by sending out the Read Start command
(BASE+0x8Ch). The read procedure starts in 50 ms. When the
Read Back procedure is ready (nAction_Ready flag), you can read
back the 64-bit Power-up DO Read Back Register in turn.

Address

R/W

Value Mapping (MSB----LSB)

BASE+0x8Ch

W

IDO[15...0]

BASE+0x8Eh

W

IDO[31...16]

BASE+0x90h

W

IDO[47...32]

BASE+0x92h

W

IDO[63...48]

Bit value:

0: Output Power MOSFET is OFF. (Initial value)

1: Output Power MOSFET is ON.

Address

R/W

Value Mapping (MSB----LSB)

BASE+0x8Ch

R

Read Back Start

BASE+0x8Eh

R

IDO[15…0]

BASE+0x90h

R

IDO[31...16]

BASE+0x92h

R

IDO[47...32]

BASE+0x94h

R

IDO[63...48]

Bit value:

0: Output Power MOSFET is OFF. (Initial value)

1: Output Power MOSFET is ON.

Advertising