ADLINK PCI-7442 User Manual

Page 76

Advertising
background image

64

Register Format

1: Function is enabled
0: Function is disabled

Address: BASE+0x3Ah
Reset Value: 0x0000h
Read/Write: R

--

ARDYS

SRDYS

RBRDYS

SOES

WIS

WDTES

HRHES

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

--

--

--

--

--

--

--

--

Bit15

Bit14

Bit13

Bit12

Bit11

Bit10

Bit9

Bit8

Bit15 - 7

Not used

Bit6

ARDYS: Flash Data Read/Write Finished Status

1: Process is not finished.
0: Process is finished.

Bit5

SRDYS: DO Data Sending Finishes Status

1: Process is not finished.
0: Process is finished.

Bit4

RBRDYS: DO Read Back Data Ready Status

1: DO read back data is not ready.
0: DO read back data is ready.

Bit3

SOES: Safety Out Enable Status

1: Function is enabled.
0: Function is disabled.

Bit2

WIS: WDT Interrupt Status

1: The WDT interrupt has asserted.
0: The WDT interrupt did not assert.

Bit1

WDTES: WDT Interrupt Enable Status

1: Function is enabled.
0: Function is disabled.

Bit0

HRHES: Hot Reset Hold Enable Status

1: Function is disabled.
0: Function is enabled.