The patient monitor pc, The patient monitor interface, System setup – Laerdal SimMan 3G Mystic User Manual

Page 23

Advertising
background image

19

20

Manikin Setup

System Setup

Setup f

or Sim

ulation

Clinical F

eatur

es

Maintenance

Tr

oubleshooting

Spar

e Par

ts

System Setup

SAVE FILES AND LAERDAL DEBRIEFVIEWER

Save the session log for later debriefing or documentation. Click
<Debrief> to start the Debrief Viewer. For more information see
section The Laerdal Debrief Viewer.

The Patient Monitor PC

The Patient Monitor PC can be purchased separately. The Patient
Monitor PC has a touch-display and is used to run the Patient Monitor
Application.

The Patient Monitor software emulates a real patient monitor as
found in hospitals and ambulances. During a simulation, learners can
observe and monitor changes in a patient’s clinical status via the
Patient Monitor software.

Video capture from the patient monitor display and the web-camera
can be stored for use in the Debrief Viewer.

The Patient Monitor PC must be started and remain connected
throughout the simulation, in order to record video and allow screen
capture for debrief files.

STARTING THE PATIENT MONITOR

APPLICATION

1 First click the Windows <Start> button, and then select the

<Laerdal SimMan3G> program folder from the Windows
programs list.

2 Select the Patient Monitor Application program in the <Laerdal

SimMan3G> program folder. The Select manikin window will
appear. Select a manikin in the list and click <OK>.

3 The Patient Monitor application will open in full screen mode.

4 If the SimMan3G program folder or the Patient Monitor

Application program is not available on your computer, see the
Patient Monitor Application - Troubleshooting section - in the
SimMan3G Help files.

The Patient Monitor Interface

3

4

1

2

1 - TOP MENU

1 - Press #wave in the top menu to view and
change monitor display settings.

Pressing the Alarm Volume icon on the top menu
line opens the <Alarm Volume> menu.

2 - Parameters readout area. The learner may also edit scaling, alarm
limits etc using this interface. Clicking the parameter of interest will
present a menu with available options.
Some fields will only be available while appropriate sensors are
connected to the Manikin.

3 - BOTTOM MENUS

There are effectively two menus. Press the left or

right arrow key to toggle back and forth.

BOTTOM MENU 1 (IN ORDER FROM LEFT TO

RIGHT):

Selecting the <Silence Alarm> button turns active
alarm sounds OFF.

Selecting the <Pause Alarms> button turns all
sound alarms off for 3 minutes.

The NBP Start begins inflation of the modified

SimMan 3G blood pressure cuff. NBP details will
register in the NBP section of the monitor.

<Zero Press> button opens a submenu from which
you can select zeroing of the ABP, PAP or CVP
transducers.

Cardiac Output generates a new reading of Cardiac
Output. The C.O. details will be shown in the C.O.
part of the Patient Monitor PC.

<The Wedge> button temporarily substitutes the
PAP wave and numbered parameters with the WP
wave and parameters. The wedge curve switches
back automatically after 10-15sec.

The TOF <Train of Four> button generates a ew

reading of the TOF state of the patient. The TOF
details will be shown in the TOF part of the Patient
Monitor PC.

Selecting the <Graph Trends> button opens the
Graphical Trends window. By using the menu
buttons, you can review the history of the available

Advertising