Airway features, Clinical features, Configurable airway features – Laerdal SimMan 3G Mystic User Manual

Page 44

Advertising
background image

41

42

Clinical Features

Airway Features

The airway is anatomically modeled as far as the bronchia.

The airways can be manipulated by a learner:
− Head tilt/Chin lift

− Jaw thrust w/ articulated jaw

− Cricoid pressure and manipulation

− Suctioning (oral & nasopharyngeal)

If the tongue fallback feature is enabled, head tilt is required to open
the airways for mask ventilations. The manikin may be ventilated by
normal and emergency methods;
− Bag-mask ventilation

− Orotracheal intubation

− Nasotracheal intubation

− Transtracheal intubation

Prior to using airway adjuncts, apply a small amount of Laerdal Airway
Lubricant
to the equipment. Do not spray lubricant directly into the
airway.

The following equipment or methods are suitable to secure the
manikin’s airway:
− Laryngeal mask airways: The airways are designed for use with

size #4, but size #5 may also seal correctly.

− Endotracheal tube intubation, size ID 7.5 - 8.5 is suitable, but

using the smaller size reduces wear of the manikin’s airways.

Use of a malleable stylet is recommended - make sure it does not
extend beyond the ET tube.
− i-Gel

− Fiberoptic intubation

− Combitube (size small adult is suitable)

− Retrograde intubation

− Needle cricothyrotomy

− Surgical cricothyrotomy

The following manikin features indicate incorrect tube placement:
− Right main stem intubation – unilateral chest rise

− Stomach distention

− Lack of chest sounds, CO

2

exhalation (see Breathing section)

CONFIGURABLE AIRWAY FEATURES

Manikin features may be configured to present various airway
Scenarios:
− The airway may be closed automatically or manually. There are

four levels of resistance and compliance within the airway.

− Tongue edema - multiple levels

− Pharyngeal swelling

− Laryngospasm

− Decreased cervical range of motion

− Trismus

− Teeth - soft upper dentures may be replaced with a hard set of

teeth for enhanced realism while practicing intubations.

During simulation, the following conditions can be set:
− Can’t intubate / can ventilate

− Can’t intubate / can’t ventilate

The following information is automatically registered in the SimMan3G
simulation session:
− Detection of proper head position.

− Jaw Thrust

− Pneumothorax decompression

− Ventilations

− Stomach distension

Instructor Mode Airway / Breathing Tab

The Airway / breathing tab shows the status of the patient’s breathing
and allows configuration of <Airway / breathing> settings.

1

3

4

5

6

7

8

2

1 - Animation and Settings

The airway/breathing animation is a real-time movie of the airway/
breathing status of the patient.

Healthy breathing with low resistance is shown by an inhalation in blue
which then turns white.