Replacing Crico Tape / Neck Skin
After creating an emergency airway through the cricothyroid
membrane, replace the perforated membrane before starting a new
simulation session.
1 Remove the neck skin (velcro fasteners behind the neck).
2 Remove the old strip of Crico tape.
3 Replace with a new Crico tape.
4 Ensure Crico-tape completely covers and seals the opening to
prevent leakage while ventilating the manikin.
Replacing Chest Drain Pleura
The chest drain module’s pleura skin should be replaced after each
use.
1 Open the torso skin and remove the module from the chest.
2 Remove the old pleura skin, and replace with a new skin and
replace the module.