Fuses - External and Internal

External Recommended Fuses:
- recommend Time Lag 6.3A
- Littelfuse 21506.3P (cartridge type, RoHS)
- Littelfuse 21506.3XEP (axial lead type)

Internal Fuses:
Our internal fuses are 6.3 Amp, slo-blow, use same or smaller for installation ahead of the
drive.
If you choose to use a circuit breaker ahead of the drive instead of using slo-blow fuses, we
recommend a surge rated 7.5 to 8.0 Amp circuit breaker.

Line Filters

We recommend Leviton 51000 series surge protection modules, which provide maximum
protection under all conditions. The Leviton modules are required for CE compliance. Corcom
10VR1 filters may be considered for non-CE compliant applications.
Surge Protector with Line Filter:
For 120VAC: Leviton 51010-WM
For 220VAC: Leviton 51240-WM

Recommended Ferrite Core Instructions

At the drive end of the leads, you must twist the power wires, and wrap those wires through
ferrite cores. 4 foot cables require one ferrite with the twisted power wires running through the
core 5 wraps. Longer cables require less turns through the cores, but more cores stacked to-
gether as one. In the case of a 10 foot cable, use two ferrite cores stacked as one, and three
wraps. For a 20 foot cable - 3 ferrite cores stacked as one, with three turns through the cores.
You may contact Applied Motion Products for technical advice if needed.