Seven segment display status codes, 9bluac5 s/q hardware manual – Applied Motion BLuAC5-Q User Manual

Page 9

Advertising
background image

9

BLuAC5 S/Q Hardware manual

920-0049 Rev. C

12/8/2014

Seven Segment Display Status codes

Memory Fault: When reading or writing to “Flash” memory an error occurred. This is
an indicator of memory problems that are typically induced with too many write cycles
(>100,000).

Serial Comm Error: Indicates a Serial Communication error. This error is also indi-
cated by the Comm Tx and Rx LEDs flashing an alternating pattern.

Positioning Mode: The drive is in Positioning Mode. This is the mode used when
performing “point to point” moves.

Velocity Mode: The drive is in Velocity Mode. This is the mode used when “Jogging”
or Analog commanded Velocity.

Torque Mode: The drive is in Torque Control Mode. This is the mode used for Analog
commanded Torque operation.

Step & Direction Mode: The drive is in Step and Direction Control Mode. This is the
mode used for “Encoder Following” or Positioning using Step and Direction input.

Si Positioning: You should not see this code on a -S or -Q drive.

Drive Disabled: The drive output is disabled.

Q Program Running: An outside segment will be rotating around the display. The
rotate rate is about 0.2 seconds per segment.

Drive Start-up test pattern: This pattern is displayed for a short period of time at
drive start-up.

Memory Fault: Q segment could not be executed because it was blank.

Serial Comm Timeout: A complete command packet was not recevied in the normal
amount of time. This can happen if you try to type SCL or Q commands into Hyper-
terminal
instead of using the SCL Utility. It will also occur if your host application
does not end each command with a carriage return (ASCII 13)