Using high speed inputs with 12-24 volt signals, 22 bluac5 s/q hardware manual – Applied Motion BLuAC5-Q User Manual

Page 22

Advertising
background image

22

BLuAC5 S/Q Hardware manual

920-0049 Rev. C

12/8/2014

BLU

Servo

Drive

IN/OUT 1

DIR+

DIR+

DIR-

DIR-

STEP+

STEP-

STEP+

STEP-

Indexer

with

Differential

Outputs

BLU Servo

Master

Encoder

GND

DIR-

DIR+

STEP-

STEP+

GND

B-

B+

A-

A+

Using High Speed Inputs with 12-24 Volt Signals

Most PLCs don’t use 5 volt logic. You can connect signal levels as high as 24 volts to the
STEP and DIR inputs if you add external dropping resistors, as shown below.

• For 12 volt logic, add 820 ohm, 1/4 watt resistors
• For 24 volt logic, use 2200 ohm, 1/4 watt resistors

WARNING: The maximum voltage that can be applied directly to a high speed input

terminal is 5 volts. Never apply high voltage AC to an input terminal.

Connecting to Indexer with Differential Outputs

(includes Applied Motion Si-100 Indexer)

Connecting to a Master Encoder

(for following applications)