In/out2 connector (-se and -qe only), Single ended inputs, Differential inputs – Applied Motion BLuAC5-Q User Manual

Page 32: Single ended inputs differential inputs, 32 bluac5 s/q hardware manual, In/out 2, Se and -qe only, Inside in/out 2

Advertising
background image

32

BLuAC5 S/Q Hardware manual

920-0049 Rev. C

12/8/2014

IN/OUT2 Connector (-SE and -QE only)

The BLUAC5-SE and the BLUAC5-QE have a second DB-25
I/O connector labeled IN/OUT 2. This provides:

8 optically isolated digital inputs IN1 - IN8

4 optically isolated digital outputs OUT1 - OUT4

one 0 - 5 volt analog input, 10 bit ADC resolution

Single Ended Inputs

IN1 - IN6 are single ended, 12 - 24V inputs. They can, as a
group, be configured to accept current sourcing (PNP) signals
by tying one of the COM terminals to the return of the I/O
power supply. If the COM terminals are connected to the + I/O power supply then the inputs
1 - 6 will accept sinking (NPN) signals. Because the input circuits are isolated, they require
a source of power. If you are connecting to a PLC, you should be able to get power from the
PLC power supply. If you are using relays or me-
chanical switches, you will need a 12-24 V power
supply. This also applies if you are connecting the
inputs to the programmable outputs of another Si
product from Applied Motion.

Differential Inputs

IN7 and IN8 are differential, 12 - 24V inputs. They
can individually be configured to accept current
sourcing (PNP) or current sinking (NPN) signals.

Note: If current is flowing into or out of an input, the
logic state of that input is low or closed. If no current
is flowing, or the input is not connected, the logic
state is high or open
.

The diagrams on the following pages show how
to connect the inputs to various commonly used
devices.

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

2

3

1

19

20

21

22

23

24

25

+5V

Out 1-

Out 2+

Out 1+

Ain Com

N/C

Ain 1

IN 8-

COM

IN 5

IN 6

IN 7+

IN 8+

IN 7-

IN 4

IN 1

COM

IN 2

COM

IN 3

Out 2-

Out 3+

Out 3-

Out 4+

Out 4-

IN/OUT 2

-SE and -QE only

2200

2200

2200

2200

2200

2200

inside IN/OUT 2

COM

COM

IN1

IN2

IN3

IN4

IN5

IN6

2200

IN7+

IN7-

2200

IN8+

IN8-

COM

1

DB-25 PIN

2
3

4
5
6

7
8
9

10

11

12

13

Advertising
This manual is related to the following products: