Captiview configuration, Items to configure, 5 captiview configuration – Doremi AccessLink User Manual

Page 38: 1 items to configure

Advertising
background image

FAL.OM.002372.DRM

Page 38 of 62

Version 1.6

Doremi Labs

5 CaptiView Configuration

The AccessLink device enables customers who do not have a Doremi Digital Cinema
Server to use the CaptiView device using SMPTE ST 430-10 and ST 430-11
protocol from a non-Doremi Digital Cinema server. There are three ways to set up the
AccessLink's CaptiView network: First, the USB method is the primary way to set up the
network of the device; second is the Ethernet Port; and the third method is to use the Serial
Port. Logging in using SSH or serial connection is required to complete the setup of the device.

5.1 Items to Configure

All the items mentioned below must be configured for a CaptiView to work properly on an
AccessLink (Figure 39, Figure 40, and Figure 41):

Network configuration:

◦ IP address

◦ Netmask

◦ Gateway

Auditorium number: Each auditorium in the theater must have its own auditorium number

assigned to the CaptiView Transmitter Dongle.

Server's IP address: The IP address of the server that is going to be used with the

AccessLink must be added to the AccessLink's configuration.

Figure 39: AccessLink

Note: The CaptiView transmitter (if connected to the AccessLink) shall at least be 20cm away
from the AccessLink antenna

– usage of a USB extension cable is needed for the CaptiView

transmitter connection.

CaptiView

Transmitter

Port

Advertising