VENTING INSTALLATION

INSTRUCTIONS

Continued

2. Rigid vent pipes and fittings have special

twist-lock connections. Assemble the desired

combination of pipe and elbows to the appli-

ance adaptor with pipe seams oriented towards

the wall or floor.

Twist-lock Procedure:

The female ends of the

pipes and fittings have four locking lugs (in-

dentations). These lugs will slide straight into

matching slots on the male ends of adjacent

pipes and fittings. (All connections must be

sealed with high temperature silicone sealant

as specified in the second warning statement

on page 11.) Push the pipe sections together

and twist one section clockwise approximately

one-quarter turn until the sections are fully

locked. See Figure 17. Note: Horizontal runs

of vent must be supported every three feet. Use

wall straps for this purpose.

3. Attach vent pipe assembly to the fireplace using

twist lock connections for rigid pipe or clamp

method for flex pipe. Set fireplace in front of

its permanent location to insure minimum

clearances. Mark the wall for a 10

3

/

4

" square

hole (for noncombustible material such as

masonry block or concrete, a 8

1

/

2

" diameter

hole is acceptable). See Figure 18. The center

of the hole should line up with the centerline of

the rigid vent pipe. Cut a 10

3

/

4

" x 10

3

/

4

" square

hole through combustible exterior wall (8

1

/

2

"

diameter hole if noncombustible). Frame as

necessary.

Figure 17 - Vent Pipe Connections

Male
Slots

Female
Locking
Lugs

Rigid Vent

Pipe

4. Three types of vent caps are available for

horizontal terminations. Two square terminals

are available; one for rigid pipe applications

and one for flex pipe applications. A round

vent termination with a slip fit connection is

also provided for rigid pipe applications to

be used when a wall thickness or off spac-

ing must be accommodated. Each may be

purchased as a kit that includes a 45° elbow

and a firestop that accommodates a square or

round termination (see Parts List for Venting

Kits and Components, page 19).

Noncombustible Exterior Wall:

Apply a bead

of non-hardening mastic around the outside

edge of the vent cap. Position the vent cap in

the center of the on the exterior wall with the

arrow on the vent cap pointing up. Attach the

vent cap with four wood screws provided (see

Figure 19). Note: Replace the wood screws

with appropriate fasteners for stucco, brick,

concrete, or other types of siding.

WARNING: Do not recess

vent termination in to any wall.

This will cause a fire hazard.

Figure 18 - Vent Opening Requirements

(Framing

Detail)

10

3

/

4

"

10

3

/

4

" Inside Framing

10

3

/

4

"

8

1

/

2

"

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall

Figure 19 - Installing Horizontal Vent

Cap (Noncombustible Exterior)

Wood Screw

Vent Cap