INSTALLATION

WALL SWITCH INSTALLATION

Since the VDVF36TPNEA/TSTEA series uses a 24

VAC current supplied from a transformer mounted

on the ignition module and is prewired for easy

connection to a wall switch (see Figure 34). The

(V)DVF36TPNA/TSTA models use a self gener-

ated millivolt current that allows you to activate

the gas control valve directly without the use of

normal household electricity (see Figure 35). Both

versions are supplied with a wall switch kit for ready

connection and mounting.

WARNING: Do not wire re-

mote wall switch to main power

supply (Standard 120v house-

hold current).

1. To remove the louvers, simultaneously pull

both top end spring latches towards the center

of the appliance until they are disengaged

from locating holes. Repeat for bottom spring

latches and pull louvers outward. Reverse the

procedure to install louvers back onto the ap-

pliance (see Figure 36).

2. Connect the 18 ga. wires from wall switch to

the gas control valve terminals marked TH

and TPTH or to the ignition module using the

pigtails and wire nut connectors supplied with

the appliance.

CAUTION: Due to high tem-

peratures, make sure wires are

not touching upper firebox.

Figure 36 - Removing Louver

Glass

Locating
Holes

Spring
Latch

Figure 35 - Wall Switch Wiring Diagram,

Millivolt Units

Note:

If any of the original wire supplied must be

replaced, use type 18 AWG-105 degree C (25 feet

length maximum) or equivalent.

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Wall Switch
(Supplied)

Route Millivolt Wires
(Supplied) Through Gas
Line Conduit Sleeve

To

Thermopile

V1

SW

SI

TS

IND

V2

L1

D

N

G

P.

Figure 34 - Wall Switch Wiring Diagram,

Electronic Units

Route 4V (Supplied)
Through Electrical
Conduit Bushing

Electrode

Transformer

Plug 10V AC
To Receptacle

18 AWG
Red Wire

To Gas V

alve

Wall Switch

(Supplied)

Make Connections
with Wirenuts
(Supplied)

Ignition
Control
Module

(Back
View)

(Back
View)

ELECTRICAL HOOKUP FOR
OPTIONAL BLOWER ACCESSORY

Before blower accessory can be operated, the ap-

pliance outlet box must be properly connected to

a standard 120 VAC power source. This must be

done when the appliance is originally installed.

Refer to Wiring Diagrams on page 33.

An outlet box with two receptacles has been sup-

plied for your convenience and is located on the

lower right side of the appliance (see Figure 37,

page 22). The variable speed controller is mounted

on a magnetic base and may be positioned any-

where within an accessible distance behind the

louvered opening (see Figure 36).

Recommended
Blower Speed
Control Location

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

V1

SW

SI

TS

IND

V2

L1

D

N

G

P.