Venting installation instructions – Desa (V)DVF36 User Manual

Page 19

Advertising
background image

www.desatech.com

56131-F

19

VENTING INSTALLATION

INSTRUCTIONS

Continued

Figure 32 - Vertical Rigid Venting

Configuration With No Horizontal Run

Vertical Venting

V = 40' max.

PARTS LIST FOR DESA VENTING
KITS AND COMPONENTS

DESA (5"/8") Pipe & Vent Kits
Number Description
VKR-58 Roof Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Flue Restrictor,

Vertical High Wind Termination,

' Pipe, 4' Pipe, Wall Firestop,

Storm Collar, Roof Flashing

[0/1 - 6/1], 6 Screws)

VKB-58

Basement Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

4' Pipe, 90° Elbow, 0 Screws)

VKS-58

Snorkel Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

36" Snorkel Termination, 4' Pipe,

1' Pipe, 90° Elbow, 6 Screws)

VKG-58 Ground Floor Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

16 Screws)

P58-48

48" Section Double Wall Pipe,

Galvanized

P58-36

36" Section Double Wall Pipe,

Galvanized

P58-4

4" Section Double Wall Pipe,

Galvanized

P58-1

1" Section Double Wall Pipe,

Galvanized

P58-6

6" Section Double Wall Pipe,

Galvanized

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been

tested and approved for elevations from 0-2,000

feet (USA) and elevations from 0-4,500 feet

(Canada)

Fireplaces for High Altitude (models ending in

-HA) are for installation above 4,000 feet only.

These fireplaces are equipped with parts specific

for higher altitudes. IMPORTANT: These fire-

places can NOT be converted to propane/LP gas.

When installing a non-high altitude fireplace at an

elevation above 2,000 feet (USA), you may need to

decrease the input rating by changing the existing

burner orifice to a smaller size. Reduce input 4%

for each 1,000 feet above sea level. Check with

your local gas company for proper orifice size

identification.

When installing this fireplace at an elevation

above 4,500 feet (Canada), check with local

authorities.
IMPORTANT:

For horizontal installations

above 2,000 feet, it is recommened that a 12"

extension pipe be added before starter elbow

(see Figure 33).

Figure 33 - Recommended 12" Extension

for High Altitude Installation

45° Starter
Elbow

Note: Install
restrictor into inner
collar of fireplace
as shown.

45° Starter
Elbow

1"
Extension