PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE
REqUIREMENTS

Determine the safest and most efficient location

for your DESA direct-vent fireplace. Make sure

that rafters and wall studs are not in the way of the

venting system. Choose a location where the heat

output is not affected by drafts, air conditioning

ducts, windows or doors. Be aware of all restric-

tions and precautions before deciding the exact

location for your fireplace and termination cap.

When deciding the location of your fireplace,

follow these rules:

• A projection may be ideal for a new addition

on an existing finished wall. Refer to horizontal

termination configurations on page 15 or verti-

cal configurations on page 18.

• Do not connect this fireplace venting to a chim-

ney flue serving a separate solid-fuel burning

fireplace or appliance.

• Due to high temperatures, do not locate this

fireplace in high traffic areas, windy or drafty

areas or near furniture or draperies.

• Never obstruct the front opening of the appli-

ance or flow of combustion and ventilation air.

Keep control compartments accessible.

• Do not locate close to where gasoline or other

flammable liquids may be stored. The appliance

must be kept clear and free from combustible

materials.

CLEARANCES

Minimum clearances to combustibles for the fire-

place are as follows:

*Back and sides of surround

0"

Vent Surfaces (side and bottom)

1"

Top Vent Surface (horizontal run)

2"

Ceiling to Opening

36"

Floor

0"

Wall to Front of Glass

36"

Perpendicular Wall to Opening of Unit

2"

Top Spacer

0"

NOTICE: This fireplace is in-

tended for use as supplemental

heat. Use this fireplace along

with your primary heating sys-

tem. Do not install this fireplace

as your primary heat source.

If you have a central heating

system, you may run system’s

circulating blower while using

fireplace. This will help circulate

the heat throughout the house.

In the event of a power outage,

you can use this fireplace as a

heat source.

MANTEL CLEARANCES

Figure 3 - Direct-Vent Fireplace

Log Set

Upper
Louver
Panel

Lower
Louver
Panel

Figure 4 - Minimum Clearances

(Peninsula Shown)

CEILING

WALL

36" Min.

36" Min.

0" Floor