Operating guidlines and maintenance instructions, Burner flame adjustment – Desa (V)DVF36 User Manual

Page 27

Advertising
background image

www.desatech.com

56131-F

7

bURNER FLAME

ADjUSTMENT

Continued

Figure 56 - Burner Removal

4. Slide burner forward off orifice and turn to

one side to clear opening in hearth pan. Be

careful not to bend or damage pilot or ignitor

element.

5. To reinstall burner, follow reverse steps

making sure air shutter on burner tube is

completely seated over orifice mount.

6. Replace log set. Close door and latch. Reattach

screen and louvers.

CAUTION: Make certain ori-

fice is fully inside venturi tube's

air shutter and that air shutter is

adjusted accordingly, see Figure

54, page 26.

OPERATING GUIDLINES

AND MAINTENANCE

INSTRUCTIONS

When lit for the first time, the appliance may emit a

slight odor for about 16 - 24 hours. This is normal and

is due to the “curing” of the logs and the “burn-in” of

internal paints and lubricants used in the manufactur-

ing process. Keep compartments, logs, burners, and

area surrounding the logs clean by vacuuming or

brushing at least twice a year. Temporary removal

of the log set may ease the cleaning of the burner and

pilot assembly. In cleaning, take care not to alter the

pilot or burner location. Be sure appliance is cool

before each maintenance session.

Glass Door

Refractories

Grate and
Logs

Burner

Hearth Pan

Louver
Assembly

CAUTION: The appliance and

logs can get very hot - Handle

only when cool.

WARNING: Turn off gas and

wall switch before servicing

appliance. Any safety screen or

guard removed for servicing the

appliance must be replaced prior

to operating the appliance.

WARNING: Make certain

wires and gas lines are not

touching the underside of the

firebox.

WARNING: Children and

adults should be alerted to the

hazards of high surface tem-

peratures, and to stay away from

the appliance to avoid burns or

clothing ignition. Young children

should be carefully supervised

when they are in the same room

as the appliance.

WARNING: Have a qualified

agency periodically inspect the

vent system at the start of each

heating season, for any obstruc-

tion which may hinder its normal

operation. Never obstruct the

flow of combustion and venti-

lation air. Keep the front of the

appliance clear of all obstacles

and materials.

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and danger-

ous operation.

Advertising