OPERATING FIREPLACE

Continued

D. Do not use this appliance if any part has

been under water. immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

1. SToP! read the safety information beginning

on page 29, column 1, before proceeding.

2. Set thermostat to lowest setting (if appli-

cable).

3. Turn off wall switch.

4. open control access panel or louver.

5. Smell for gas, including near the floor. If

you smell gas, SToP! Follow “B” in the

safety information. if you don’t smell gas,

go to the next step.

6. The electrode is located by the main

burner.

7. Turn main burner wall switch to the oN

position for ignition. There will be a spark

at the electrode.

8. replace control access panel or louver once

there is a flame at the burner.

• if burner will not stay lit after several

tries, flip wall switch to OFF and call your

service technician or gas supplier.

E

A

O

L

H

I

L

PI OT

Inlet
Pressure

Figure 61 - Electronic Control Valve

Outlet
Pressure

Flame
Adjustment
Knob

From Gas
Supply

To
Main
Burner

Figure 62 - Electrode

TO TURN OFF GAS

TO APPLIANCE

1. Turn off all electrical power to appliance if

service is to be performed.

2. remove control access panel or louver.

3. Close gas valve.

SPECIFICATIONS

Models (V)DVF36TPNA-(A),
(V)DVF36TPNPEA-(A), (V)DVF36TSTA-(A)
AND (V)DVF36TSTEA-(A)

• Input Rating: 35,000/23,300 Btu/Hr

• Fuel: Natural Gas

• Manifold Pressure: 3.5" W.C.

• Minimum Supply Pressure: 4.5 W.C. **

• Maximum Supply Pressure: 10.5" W.C.

• Orifice Size (0-4500 ft.): #34 DMS
Models (V)DVF36TPNPA-(A),
(V)DVF36TPNPEA-(A), (V)DVF36TSTP-(A)
AND (V)DVF36TSTPEA-(A)

• Input Rating: 31,000/20,000 Btu/Hr

• Fuel: Propane/LP Gas

• Manifold Pressure: 10.0" W.C.

• Minimum Supply Pressure: 11.0 W.C. **

• Maximum Supply Pressure: 13.0" W.C.

• Orifice Size (0-4500 ft.): #51 DMS

**For purpose of input adjustment.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so,

contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation, or troubleshooting. If so, contact DESA’s

Technical Service Department at 1-866-672-6040.

When calling, please have your model and serial

numbers ready.

You can also visit DESA’s Technical Services web

site at www.desatech.com.

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they can’t supply original replacement part(s)

call DESA’s Technical Service Department at

1-866-672-6040 for referral information.

When calling DESA, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the