4

2. Prepare incoming gas line and check with

local codes regarding the use of teflon tape.

Complete your gas line installation by con-

necting incoming gas line with flexible gas

line. Secure tightly with a wrench, but Do

NoT overTiGhTeN.

WARNING: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is open, ap-

ply a soap and water solution

to all connections and joints. If

bubbles appear, leaks can be de-

tected and corrected. Do not use

an open flame for leak testing

and do not operate any appliance

if a leak is detected.

WARNING: Improper installa-

tion, adjustment, alteration, ser-

vice, or maintenance can cause

injury or property damage. Refer

to this manual. For assistance or

additional information, consult

a qualified installer, service

agency, or gas supplier.

INSTALLATION

Continued

GAS SUPPLY TESTING

Note:

This section is intended as a guide for

qualified service technicians installing gas to the

appliance.

CAUTION: Do not connect

appliance before pressure test-

ing gas piping. Damage to the

gas valve may result and an un-

safe condition may be caused.

The millivolt system with a manual HI/LO ap-

plies only to the (V)DVF36TPNA/TSDTA and

(V)DVF36TNPA/TSTPA models. The gas control

valve is accessible from the lower control com-

partment. Two pressure taps are provided on the

gas control valve for a pressure gauge connection

(see Figure 44).

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Figure 44 - Millivolt Control Valve

Pilot
Adjustment Cap

ON/OFF
Knob

Outlet
Pressure

Inlet
Pressure

Pilot Gas Line
Do Not Kink To Pilot

Burner

To Main
Burner

Flame
Adjustment
Knob

E

A

O

L

H

I

L

PI OT

To Main
Burner

Outlet
Pressure

Inlet
Pressure

Flame
Adjustment
Knob

From
Gas
Supply

Figure 45 - Electronic Control Valve

INSTALLING LOG SET

Before proceeding, make sure the gas control valve

is in the “OFF” position. Logs have been shrink

wrapped on a cardboard backing to prevent break-

age during shipping. Cut around perimeter of each

log and pull gently on shrink-wrap to expose log.

Do not pull on log to release it from the shrink-

wrap as this may damage logs.
1. Remove lower louver access panel in fire-

place (see step 1 of Wall Switch Installation,

page 21).

2. Remove screen rod by sliding it either to the

left or right of the fireplace until one of the

rod ends is free and completely remove the

screen from the fireplace.

3. To open the glass door, undo latches located

on the top and bottom of the firebox (see

Figure 46, page 25). Note: Use caution when

opening these latches. Carefully open the door

by swinging it to the left. The glass door is

mounted to the firebox with 5 screws.

T h e e l e c t r o n i c s y s t e m a p p l i e s t o

t h e ( V ) D V F 3 6 T P N E A / T S T E A a n d

(V)DVF36TPNPEA/TSTPEA models (see

Figure 45).

Advertising