Wiring diagrams, Service hints, Technical service – Desa (V)DVF36 User Manual

Page 33: Troubleshooting, Continued remedy, Possible cause, Problem

Advertising
background image

www.desatech.com

56131-F

33

TROUbLESHOOTING

Continued

REMEDY

1. Check electrical connections

and replace wall switch

1. Clean and adjust main burner

2. Adjust ignitor location for

maximum flame impingement

on sensor

3. Have vent inspected for block-

age or damage

POSSIBLE CAUSE

1. Wall switch wires defec-

tive

1. Burner flame is too low

2. Igniter is misaligned causing

safety burner to "drop out"

3. Vent may be blocked or

restricted

PROBLEM

No gas to main burner when wall

switch and valve are set to ON

position

Frequent main burner outage

WIRING DIAGRAMS

GND

J. BOX RECEPTACLE

GRN

BLK

WHT

BREAKER)

GRN

(NOT SUPPLIED)

INCOMING
120V AC

(FUSE BOX

FIELD WIRE

WHT

BLK

OR

CONNECTORS

Variable
Speed
Control

Blower

Electrical Rating:
120v, 60Hz, 0.7A

TRANSFORMER

STEP DOWN

120V AC

24V AC

OFF

WALL SWITCH

(SUPPLIED)

ON

IGNITER

ASSEMBLY

D V2

G
N

L1 IND

IGNITION CONTROL

MODULE

TS S1

SW V1

P.

120 VAC

GND

J. BOX RECEPTACLE

OPTIONAL

CONTROL

REMOTE

GRN

BLK

WHT

BREAKER)

GRN

(NOT SUPPLIED)

INCOMING
120V AC

(FUSE BOX

FIELD WIRE

WHT

BLK

OR

CONNECTORS

E

A

I

H

L

O

I

P

T

O

L

CONNECT

VALVE TO

CONTROL

DO NOT

GAS VALVE

Figure 63 - Electronic Wiring Diagram

Figure 64 - Optional Blower Wiring Diagram

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so,

contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation, or troubleshooting. If so, contact DESA’s

Technical Service Department at 1-866-672-6040.

When calling, please have your model and serial

numbers ready.

You can also visit DESA’s Technical Services web

site at www.desatech.com.
Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

Advertising