Pre-installation preparation, Unit, Continued – Desa (V)DVF36 User Manual

Page 7: Framing

Advertising
background image

www.desatech.com

56131-F

7

0"

36"

2"

Wall In Front Of Glass

36" Min.

Perpendicular

Wall 2" Min.

From Opening

Right Side

Surround

(0" Min.)

Left Side

Surround

(0" Min.)

TOP VIEW

Figure 6 - Mantel Clearances for

Peninsula and See-Thru Fireplaces

(Peninsula Shown)

21" Min.

15" Min.

12" Min.

4"

Min.

7" Min.

1

1

/

2

" Max.

UNIT

Spacer

 x 4

Combustible
Material May
Be Used

Drywall (Gypsum
Board, Sheetrock, Etc.)

Safe Zone for
Projection of
Combustible
Material

Woodwork, such as wood trims, mantels and other

combustible materials should not be placed within

7" of the opening of this fireplace (see Figure 6).

Combustible material above projecting more than

1

1

/

2

" from the appliance’s front face must not be

placed less than 15" from the opening of the appli-

ance, (ref. NFPA Standard 211 Sec. 7-3.3.3)

PRE-INSTALLATION

PREPARATION

Continued

Figure 5 - Minimum Clearances

(See-Thru Shown)

Combustible Material

Drywall

 x 4

Stud

Minimum 1" Clearance from
Side (Only for See-Thru)

FRAMING

Once the final location has been determined, ob-

serving clearances for the vent termination, you

may construct framing using dimensions shown

in Figures 7 to 13 depending on your particular

installation

If the appliance is to be installed directly on carpeting,

tile (other than ceramic), or any combustible mate-

rial other than wood flooring, the appliance must be

installed upon a metal or wood panel extending the

full width and depth of the appliance. There are three

holes on each side of the bottom of the unit where

screws can be used to secure the unit to the floor.

The gas supply line may be connected through the

side framing or alternately through the lower sub-

flooring or a platform base if provided (see Figures

10 and 11, page 8). Depending on installation, refer

to appropriate illustrations.

Figure 7 - Rough Opening for Installing

Peninsula Fireplace

39

3

/

4

" Min.

40

1

/

2

"

23

5

/

8

"

39

3

/

4

"

Min.

40

1

/

2

"

23

5

/

8

"

*

Figure 8 - Rough Opening for Installing

Peninsula Fireplace on Platform

* As required by design as long as

ceiling clearance is maintained.

Platform
Must Be
Solid, Flat,
and Fully
Supported