Installation, Gas line hook-up, Continued – Desa (V)DVF36 User Manual

Page 23

Advertising
background image

www.desatech.com

56131-F

3

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Gas
Valve

To Thermopoile

Extension

Cord

Outlet Box

White

Red

Figure 40 - Installing Remote Receiver

(SKYTECH Model)

Optional Fan
Kit Plug

Receiver

Pull to Remove
Insulation Tab

Battery
Cover

1 Volt
Battery

Figure 41 - Installing Battery in Hand-

Held Remote Control Unit (SKYTECH)

GAS LINE HOOK-UP

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

WARNING: Gas line hookup

should be done by your gas

supplier or a qualified service

person.

An equipment shutoff valve has been included in

the appliance’s gas supply system. You may con-

sider installing an extra gas shutoff valve outside

the appliance’s enclosure (check with local codes)

where it can be accessed more conveniently with a

key through a wall as shown in Figure 42.

Route a 1/2" NPT black iron gas line towards the

appliance coming in from the left. It is recom-

mended to route the pipe between the stand of

the firebox and the surround of the fireplace (see

Figure 43).

INSTALLATION

Continued

IMPORTANT:

The appliance and its individual

shutoff valve must be disconnected from the gas

supply piping system during any pressure testing

of that system at test pressures in excess of 1/2

psig. (3.5 kPa). The appliance must be isolated

from the gas supply piping system by closing its

individual equipment shutoff valve during any

pressure testing of the gas supply piping system

at test pressures equal to or less than 1/2 psig.

(3.5 kPa).

CAUTION: Do not kink flex-

ible gas line.

CAUTION: Compounds used

on threaded joints of gas piping

shall be resistant to the action

of Liquefied Petroleum (LP or

propane), and should be applied

lightly to ensure excess sealant

does not enter the gas line.

1. Install a sediment trap between the incoming

gas line and the gas control valve (see Figure

43). The sediment trap should extend down the

center of the pipe. Refer to your local codes.

3" Min.

Side W

all

Of Appliance

Incoming 1/" Gas
Line Permitted by
Local Codes

Figure 43 - Sediment Trap

Sediment
Trap (Not
Supplied)

Figure 42 - Typical Exterior Wall Gas

Shutoff Installation

Key

Extension

Shutoff Valve