VENTING INSTALLATION

INSTRUCTIONS

Continued

Combustible Exterior Wall:

For vinyl siding,

stucco, or wood exteriors, a siding standoff

must be installed between the vent cap and

exterior wall. The siding standoff prevents

excessive heat from damaging siding materials.

Siding materials must be cut to accommodate

standoff. Bolt the vent cap to the standoff.

Apply non-hardening mastic around outside

edge of the standoff. Position the standoff/cap

assembly in the center of the square hole and

attach to exterior wall with wood screws pro-

vided (see Figure 20). The siding standoff must

sit flush against the exterior fascia material.

5.

Combustible Exterior Wall Only:

Slide

interior wall firestop over vent pipe before

connecting horizontal run to vent cap (see

Figure 21).

6. Make final connection to vent terminal.

Flush or recessed with short vent system:

Vent system may be pre-sized. Check for final

fit and slide unit into framing with firestop in

place. This is helpful when using rigid pipe

and round vent termination. Vent may be

preconnected and slipped through firestop.

Make sure the 45° connection at unit is tight

and does not come loose before unit is nailed

to framing.

Square vent or long vent configuration:

Vent

pipe must be manipulated at outer end to make

final connection. Manually secure pipe inside

open framing. If this is a retrofit installation in

an inaccessible space, you may have to secure

the outer end of vent pipe with wall straps and

tap screws at outer end.

When using tap screws with rigid pipe, be sure

that screws do not penetrate inner pipe. These

procedures may also be followed by flexible

pipe installations. To use flexible pipe, vent

must be drawn through end firestop, cut back

to 6"-8" to permit easy connection of flex

termination and connection must be slipped

back into and secured to installation. You

must use an adequate number of spring spac-

ers at ends and closest bend to termination to

prevent kinks or collapsing on the fire. Do not

use screws with flex pipe. Vent system must

be code inspected and released before adding

dry wall or other surface treatments.

Figure 20 - Installing Vinyl Siding

Standoff (Combustible Exterior Wall)

Cut Vinyl Siding
Away to Fit Standoff

Wood
Screw

Bolt

Standoff

Vent
Cap

Apply Mastic
to All Four Sides

Vent Cap
(Horizontal Termination)

Interior Wall
Surface

Interior Wall Firestop
(Combustible
Exterior Wall Only)

Horizontal
Vent Pipe

Figure 21 - Connecting Vent Cap with

Horizontal Vent Pipe

Screw