Pilot/electrode assembly adjustment, Burner flame adjustment, Installation – Desa (V)DVF36 User Manual

Page 26

Advertising
background image

www.desatech.com

56131-F

6

Figure 52 - Correct Pilot Flame Pattern

1/8"

(0.3cm)

3/8" - 1/2"

(.95cm-1.3cm)

1/2"
(12.7 mm)

3/4"
(19 mm)

Edge of Burner

Top of
Burner

Figure 53 - Correct Ignitor Location

(Side View)

bURNER FLAME

ADjUSTMENT

The air shutter, located at the base of the main

burner (see Figure 54), has been factory preset

to the proper air-to-gas ratio which results in an

even, clean burning flame across the burner (see

Figure 55). If readjustment is necessary, you can

restore the proper air-to-gas ratio by loosening the

air shutter screw and rotating the air shutter until

the proper flame setting is achieved (the shutter's

normal setting is fully open. Do not forget to

retighten the air shutter screw.

Figure 55 - Burner Flame Patterns

Figure 54 - Air Shutter Adjustment

Air Shutter

Air
Opening

Burner

Venturi
Tube

Burner Gas Line

CORRECT

INCORRECT
CLOSE
SHUTTER

INCORRECT
OPEN SHUTTER

Short, Sharp, Blowing Flame

Long, Blue Flame with

Yellow Tips

Long, Uneven, Yellow Flame

Firebox Bottom

Adjustment
Screw

Orifice

BURNER REMOVAL

CAUTION: Before proceed-

ing to open glass door or handle

logs, make sure the entire unit

is cool.

1. Remove top and bottom louvers and screen as-

sembly. Undo 4 latches and open glass door.

2. Carefully remove the log set intact and set

aside (see Figure 56, page 27).

3. Remove the 2 screws holding burner to hearth

pan.

DECORATIVE FACING

Any noncombustible material may be used for

facing (glass, tile, brick, etc.) as long as the proper

clearances are observed (see Clearances, page 6).

IMPORTANT:

Louvered openings must not be ob-

structed, and upper and lower panels must remain

removable for servicing. Use only heat-resistant,

noncombustible mortar or adhesive when securing

facing material.
Note:

Combustible material, such as wood, that

has been fireproofed is not considered noncom-

bustible.

PILOT/ELECTRODE

ASSEMbLy ADjUSTMENT

The pilot assembly is factory preset for the proper

flame height. Alteration to these settings may have

occurred during shipping and handling. If this is the

case, some minor adjustment may be necessary and

should be done by a qualified technician. To access

the pilot assembly, the glass door must be opened.

The proper settings for the thermopile height should

be at a distance of 3/8" to 1/2" from the pilot flame

as shown in Figure 52.

The electrode is installed at the factory for proper

positioning. However, alterations to the position

may have occurred due to shipping and handling.

These settings may need adjustment and must be

done by a qualified technician. The correct position

and height is as shown in Figure 53.

INSTALLATION

Continued

Advertising