AMETEK MX Series Rev: AY User Manual

Page 14

Advertising
background image

User Manual – Rev AY

AMETEK Programmable Power

MX Series

14

2.1.2 Output

Note: All specifications are for AC and DC unless otherwise indicated.

Output Parameter

MX30

MX45

MX60

MX90

MX135

Modes

Std

Controller

AC, DC

Pi

Controller

AC, DC, AC+DC

Voltage:

Ranges (L-N):

AC Mode

Low: 0 - 150 V / High: 0 - 300 V

DC Mode

Low: 0 - 200 V / High: 0 - 400 V

AC+DC Mode

AC: Low: 0 - 150 V / High: 0 - 300 V
DC Offset: Low Vrange: 0 - 150 V

High Vrange: 0 - 220 V (Series II) / High; 0 – 250 V (Series I).

Note:

On MX units with standard controller, only one voltage range is available
unless the -R range change option is installed.

Resolution:

AC Mode

0.1 V

DC Mode

0.1 V

AC+DC Mode

AC:

0.1 V

DC Offset:

Series I

0.01 V

< 2.5 V

0.1 V

2.5 - 25 V

1 V

> 25 V

Series II

0.01 V

Accuracy:

± 0.3 V AC mode
± 1 V DC mode

Distortion THD

1

:

(Resistive full
load)

MX units shipped before 2009
< 1 % @ 16 - 66 Hz
< 2 % @ 66 - 500 Hz
< 3 % @ > 500 Hz

MX units shipped as of 2009
< 0.5 % @ 16 - 66 Hz
< 1.00 % @ 66 - 500 Hz
< 1.50 % @ > 500 Hz

Load Regulation:

0.25 % FS @ DC - 100 Hz

0.5 % FS @ > 100 Hz

Line Regulation:

0.1% for 10% input line change

DC Offset Voltage:

< 20 mV

1

The distortion specification for the MX Series is valid for pure (inductance < 12 uH) resistive load conditions and using a

30 KHz LP filter on distortion meter.

Advertising