AMETEK MX Series Rev: AY User Manual

Page 200

Advertising
background image

User Manual - Rev AV

AMETEK Programmable Power

MX Series

200

Frequency

380

390

360

360

Table 9-1: Normal Voltage and Frequency Minimum

Standard/Group

RTCA

Group1

Group2

Group3

Voltage

1

122

122

122

122

3

120.5

120.5

120.5

120.5

Frequency

420

410

650

800

Table 9-2: Normal Voltage and Frequency Maximum

This test will set the voltage and frequency to levels defined by Table 9-1. The test will last for 30
minutes. The test will be repeated for the Group 2 and 3 using the Voltage setting from Table 9-2
and the frequency from Table 9-1. The

←

key (backspace) will terminate the test at any time.

VOLT FREQ MAX

This test will set the voltage and frequency to levels defined by Table 9-2. The test will last for 30
minutes. The test will be repeated for the EURO standard using the Voltage setting from
Table 9-1 and the frequency from Table 9-2. The CLR Key in local operation will terminate the test
at any time. Group execute trigger will terminate the test remotely. The unselected phases will
remain at 115 volts. The

←

key (backspace) will terminate the test at any time.

VOLT UNBALANCE

Standard/Group

RTCA

Group1

Group2

Group3

Voltage offset

6

6

6

9

Frequency

400

400

360/650

360/800

Table 9-3: Normal Voltage Unbalance

This test will change the output voltage for each phase from 115 volts to 115V + offset. Refer to
Table 9-3 for the offset value and the Frequency. The test will last 30 minutes. The test will be
repeated for a second Frequency if applicable. The test can be terminated at any time.
The

←

key will terminate the test at any time.

WAVEFORM DISTORTION

This test will generate a 5% THD voltage distortion on the output voltage waveform. The
distortion is generated by using a clipped sine wave. The test will last for 30 minutes. The

←

key (backspace) will terminate the test at any time.

VOLTAGE MODULATION

This test requires a numeric value entry equal to the modulation rate in Hz. This entry value
must be between 1 Hz and 200 Hz. The amplitude modulation is calculated based on the
modulation rate as defined in Figure 9-4. This test will last for 2 minutes.