4.2 Compressor Controls


The 527 Compressor provides a comprehensive suite of controls:

THRESHOLD: The level at which compression begins

ATTACK: The time it takes for the compressor to respond

RELEASE: The time it takes the compressor to return to unity gain

RATIO: The amount of compression applied after threshold

TYPE: NEW or OLD detection path topology

KNEE: The characteristic of the response curve at the onset of compression.

THRUST®: Patented circuit that inserts a high-pass filter before the RMS detector

GR Meter (GAIN REDUCTION): 10 LED gain reduction meter

LINK: Activates the DC LINK for stereo/multichannel processing with other TCS units

COMP BYPASS (Compressor Bypass): Completely removes the 527 Compressor from

POST EQ: Moves the 527 Compressor to post the 550A Equalizer in the audio path

4.2.1 Threshold

THRESHOLD: Sets the level at which compression begins

Continuously variable between +10dBu and -20dBu

Detented rotary pot for easy recall

4.2.2 Attack and Release

Attack and Release times are fully variable on the 527 Compressor and share a

dual-concentric potentiometer for control. Attack time is adjusted using the

outer ring of the pot and Release time is adjusted using the inner knob.

ATTACK: Sets the time it takes the compressor to react when the level exceeds

the set THRESHOLD

Continuously variable between 1 and 25 ms (milliseconds)

Detented rotary pot for easy recall