0 signal flow and block diagrams, 1 default signal flow, 2 alternate routing – API Audio The Channel Strip User Manual

Page 5: 1 compressor post eq, 2 compressor bypass

Advertising
background image

2.0 Signal Flow and Block Diagrams

2.1 Default Signal Flow

With no routing switches engaged, the default signal flow through The Channel Strip is illustrated by the
left-to-right order of the unit’s front panel:

512C Preamp ----------> 527 Compressor --------------> 550A Equalizer---> Insert --> Output

2.2 Alternate Routing

The default signal flow can be modified in four (4) ways:

The 527 Compressor can be moved after the 550A Equalizer

The 527 Compressor can be hard bypassed

The 550A Equalizer can be hard bypassed

Insert Return can be engaged

Since each of these routing functions are independent of each other, multiple signal flow configurations
are possible. Combined with the open interfacing available on the rear panel, comprehensive and

flexible routing possibilities are available to meet most production needs.

2.2.1 Compressor Post EQ

Engaging the POST EQ switch will move the 527 Compressor to after the 550A Equalizer. When

the POST EQ switch is engaged, the signal flow will be as follows:

512C Preamp -----> 550A Equalizer -----> 527 Compressor -----> Insert -----> Output

POST EQ: Moves the 527 Compressor to after the 550A Equalizer

527 will use Second Effect rear panel interface jacks

Illuminates when engaged

2.2.2 Compressor Bypass

Engaging the COMP BYPASS switch will completely remove the 527 Compressor from the signal

path using a relay-based hard bypass. The 527 Compressor will be bypassed regardless of its
assigned position in the signal flow. When the COMP BYPASS switch is engaged, the signal flow

will be as follows:

512C Preamp -----> 550A Equalizer -----> Insert -----> Output

COMP BYPASS: Removes the 527 Compressor from the signal flow

527 will not be accessible via rear panel interface jacks

Illuminates when engaged