2 soft mute, 1 remote mute control, 3 vu meter – API Audio The Channel Strip User Manual

Page 26

Advertising
background image

CHANNEL OUT: Main Channel Strip output

Fed from 325 Line-Driver

Balanced, low-impedance +10dBu line level

Male XLR connector

6.2.2 Soft Mute

CUT: Mutes main output

Silent soft mute

Remote control via 9-pin D-sub connector on the rear panel

Illuminates in red when engaged

6.2.2.1 Remote Mute Control


The soft mute (CUT) can be remotely controlled via the EXT. MUTE COMMANDS connector

on the rear panel. The remote circuit operates in parallel with the on-board CUT switch, but

overrides the on-board CUT switch when activated.

EXT. MUTE COMMANDS (External Mute Commands): Control port for

the soft mute (CUT) switch

Overrides on-board CUT switch when activated

9-pin D-sub connector

9-pin D-sub pin-out for remote mute control:

Pin 1 – 5V gnd

Pin 6 - +5V

Pin 9 – Cut switch output active low

Pin 5 – External mute command input active +5V high

6.2.3 VU

Meter

The VU meter will normally display the output of the 325 Line-Driver.

The output of the 512C Preamp will be displayed the when the VU PRE switch is engaged.

VU PRE (VU Preamp): Routes the output of the 512C Preamp to the VU meter input

Illuminates when engaged