4.2.4.2 NEW:

Feed-Forward

Compression


In a feed-forward compressor, the RMS detector normally gets its signal from a split of the

input signal. (The detector path can alternately get its signal from a Side Chain Input.) With

this method, the RMS detector sends a signal to the VCA that is an exact ratio of the desired

compression set by the RATIO control. This is how many new VCA based compressors work.
This can yield more aggressive compression and a harder, more affected sound.

4.2.5 Knee


Knee determines the 527 Compressor’s response curve at the onset of compression.

The 527 Compressor has two (2) knee settings that control how the compressor transitions into
compression:

SOFT: Rounded response curve

HARD: Sharp response curve

The knee of the compressor is selected using the KNEE switch.

KNEE: Selects the response curve at the onset of compression.

SOFT: Rounded response curve (default setting with switch disengaged)

HARD: Sharp response curve (switch engaged)

Illuminates when engaged