CPLD and FPGA
ATCA-8310 Installation and Use (6806800M72E)
260
8.1.5.3.4 Configuration CRC Error
During normal operation the operation the Configuration is periodically checked by dedicated
FPGA internal logic. In the case of a CRC error the signal CONF_CRC_ERR is asserted to signal
the system, that FPGA logic may be corrupted.
Such an error is handled like a power failure.
8.1.5.4
CPLD Serial Redirection
Figure 8-2
CPLD Serial Redirection
IPMC_TXD
IPMC_RXD
IPMC_COM2FP
CPLD
IMPC
Debug
FPGA
COM1
3
PinHeader
Face
Plate
COM1
FPGA_COM1_TXD
FPGA_COM1_RXD
IPMC_RXD_CON
FP_COM1_TXD
FP_COM1_RXD
IPMC_COM2FP
=0
or
SWITCH[4]on:
IPMC_COM2FP
=1
or
SWITCH[1]on: