Table 8-134, Fault event enable register, Cpld and fpga – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual
Page 330

CPLD and FPGA
ATCA-8310 Installation and Use (6806800M72E)
330
5
DMC Base Fault
0: No event
1: DMC Base Fault occurred.
Ext.
SPP: r/w1c
6
DMC 1 Fault
0: No event
1: DMC 1 Fault occurred.
Ext.
SPP: r/w1c
7
DMC 2 Fault
0: No event
1: DMC 2 Fault occurred.
Ext.
SPP: r/w1c
8
RTM Fault
0: No event
1: RTM Fault occurred.
Ext.
SPP: r/w1c
9
SPP Reset:
0: No event
1: SPP reset occurred or power-up cycle
Note: Bit is not maskable
1
SPP: r/w1c
15:10
Reserved
0
r
Table 8-134 Fault Event Enable Register