background image

Diagnostics & Troubleshooting 10-3

C h e ck i n g S u p p l y Q u a l i t y

The printer continuously stores data from the most recent 16 supplies printed
to check the reflectivity of the sensor marks on the supply. Before you
check your supply quality, print a batch of supplies or test labels.

1. From the Diagnostics menu, press  or  until you see

DIAGNOSTICS

 User Diag

2. Press Enter/Pause. You will be at the User Diagnostics menu.

Press

 or  until you see

USER DIAG

Supply Qualit y

3. Press Enter/Pause. If you have not printed any labels, the message "No

data! Press Enter" appears. You will also see the "No data! Press
Enter" message if you are using continuous (non-indexed) supplies.
If you have printed labels since turning on the printer, you will see

Len Min Max OK
 1568 034 124 Y 

The Len listing is the length of the loaded supply in dots.

The Max listing should always be greater than the Min listing. The
OK listing tells whether the sense mark on the supply passed a
detection test. Press

 or  to see the other readings.