Set motor parameters:

š Mark the symbol „Motor parameters“ .
š Press the

key until the following will be displayed:

Pull: 75

5400

[ 4500]

MAX.: 8000

MIN.: 400

DEC.

80%

ACC.

100%

RESET

ON

SETUP-02

67

š Use the

keys to mark the different values in

the window.

š Use the

keys to adjust the desired values:

RESET

must be set to ‘ON’.

MIN.:

minimum revs of the sewing head; 400 is the optimized
value.

MAX.:

maximum revs of the sewing head:
Pegasus S52:

8000

PUL.:

mounted belt drive disc size; must be set to ‘75’

ACC.:

acceleration curve; must be set to ‘100%’

DEC.:

decrease parameter: must be set to 80%

KP:

add. motor break; must be set to 16

š Press the

key to close the page.