Interface Timing

Timing and Handshaking depend upon the connection mode.

Our Centronics mode supports the BUSY-WHILE-STROBE busy signal timing and ACK-INBUSY as
BUSY-ACK relationship.

Legend

Time interval

Min.

Max.

all times in µs

A

Data Setup Time

1.0

B

Strobe pulse width

1.0

500

C

Data hold time

1.0

t

Busy while Strobe

0.25

1.0

a

Ack in Busy

0

2.5

/STROBE

DATA

/ACK

BUSY

Figure 54. Mode Centronics