Esc p1; pn l, Esc [ p1; p2 sp, Esc p – Compuprint 4247-L03 Programmer Manua User Manual

Page 97: Esc [ p, Resets mode (rm) (ansi), Selects emulation (emu) (ansi)

Advertising
background image

The proprietary defined parameter values are:

p

MNEMONIC MODE

FUNCTION

1

PRM0

Proportional Print Mode

3

CSI

Single Character CSI Mode

4

BLD

Bold Mode

5

CS2

Character Set 2 Mode

The ANSI defined parameter values are:

p

MNEMONIC MODE

FUNCTION

0

Ignored

20

LNM

Auto CR on LF

ESC p

1

; p

n

l

Resets mode (RM).

ASCII Code

ESC p

1

; p

n

l

Hexadecimal Value

X'1B' X'5B' p

1

X'3B' p

n

X'6C'

Decimal Value

27 91 p

1

59 p

n

108

This sequence resets the print mode(s) indicated by the p1/pn parameter(s).

ESC [ p

1

; p

2

SP~

Selects emulation (EMU).

ASCII Code

ESC [ p

1

; p

2

SP~

Hexadecimal Value

X'1B' X'5B' p

1

X'3B' p

2

X'20' X'7E'

Decimal Value

27 91 p

1

59 p

2

32 126

This sequence selects the emulation according to p values. The p

1

parameter is an emulation identifier

value while p

2

is a reset control value.

The proprietary defined parameter values are:

p

1

p

2

FUNCTION

0

ANSI

1 - 20

Reserved

21

IBM Proprinter XL 24/24E

22

EPSON LQ 1050

0

Hold values (default). The current settings remain valid after changing the printer emulation.

1

Full reset. The status of such parameters reverts to defaults dependent on the selected
emulation.

To select ANSI mode from the Proprinter XL 24 mode and maintain the parameters, the sequence would
be: <ESC>[0; 0<SP>~ Leading zeros and defaulting parameters are not guaranteed to be parsed and
therefore should not be used by the application. Parameter p

1

& p

2

will be expressed as ASCII, not binary,

values. In the example above, “0” is “30H”, not “00H”.