8–5
In order to view the full response messages, use of the HyperTerminal terminal emulation
program configured as a Telnet client is permissible.
Configure HyperTerminal as follows:
1. Be sure to properly define the “Connect To” Telnet connection properties (File
Properties), as shown below at the near right:
A) Enter the CDM-625’s
Management IP Address as
the Host Address (e.g.,
192.168.1.1).
B) Enter TCP Port 23 as the Port
number.
C) Set Connect using to TCP/IP
(Winsock) instead of COM1 or
COM2.
2. For ASCII Setup (File Properties Settings ASCII Setup), as shown above at the far
right:
A) Check the "Send line ends with line feeds" option in the ASCII Sending section.
B) Check the "Append line feeds to incoming line ends" option in the ASCII Receiving
section.
An example of login and remote command/query execution, when using HyperTerminal as the
interface, appears as follows: