9–18
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes between 48 and 57)
Response to Command
(Target to controller)
Query
(Code and
qualifier)
Response to query
(Target to controller)
NTP Server
Primary
NSP=
15 bytes
numerical
Command or Query.
Sets or returns the NTP primary server in theform
aaa.bbb.ccc.ddd, where (permitted ranges are specified, but
they cannot all be zero):
aaa 0-223
bbb 0-255
ccc 0-255
ddd 0-255
Note: The NTP primary server address can be cleared by
setting it to 0.0.0.0
Example: NSP=010.006.030.001
NSP=
NSP?
NSP*
NSP#
NSP?
NSP=xxx.xxx.xxx.xxx
(see description of
arguments)
NTP Server
Secondary
NSS=
15 bytes
numerical
Command or Query.
Sets or returns the NTP secondary server in the form
aaa.bbb.ccc.ddd where (permitted ranges are specified, but
they cannot all be zero):
aaa 0-223
bbb 0-255
ccc 0-255
ddd 0-255
Note: The NTP secondary server address can be cleared
by setting it to 0.0.0.0
Example: NSS=010.006.030.001
NSS=
NSS?
NSS*
NSS#
NSS?
NSS=xxx.xxx.xxx.xxx
(see description of
arguments)
Number of
Unread Stored
Events
N/A
3 bytes, numerical Query only.
Sets or returns the number of Stored Events that remain
unread in the f orm xxx.
Note: This means unread over the remote control. Viewing
the stored events from the front panel of the Switch does
not affect this value.
Example: NUE=098
N/A
NUE?
NUE=xxx
(see description of
arguments)