B.3 crs-500 dsu tmi user data connectors – Comtech EF Data CRS-500 User Manual

Page 204

Advertising
background image

CRS-500 1:N Redundancy System

Revision 2

Appendix B

MN-CRS500

B–6

B.3

CRS-500 DSU TMI User Data Connectors

B.3.1 CRS-316 TMI – EIA-422/530, V.35, Sync EIA-232 Connector (DB-25F)

This “J2” DB-25F connector provides the EIA-232/422/V.35 User Data Interface on the CRS-316 TMI.

Table B-4. “J2” EIA-422/530 / V.35 / Sync EIA-232 User Data Connector

Pin #

Generic Signal Description

Direction

EIA-422/EIA-530

V.35

EIA-232

Circuit No.

1 Shield

-

Shield

FG

AA

101

14

Transmit Data B

DTE to Modem

SD B

SD B

-

103

2 Transmit Data A

DTE to Modem

SD A

SD A

BA

103

15

Internal Transmit Clock A

Modem to DTE

ST A

SCT A

DB

114

3 Receive Data A

Modem to DTE

RD A

RD A

BB

104

16

Receive Data B

Modem to DTE

RD B

RD B

-

104

4 Request to Send A / Ready for Receiving A

DTE to Modem

RS A

RS A

17

Receive Clock A

Modem to DTE

RT A

SCR A

DD

115

5 Not used

18

Not used

6 DCE Ready A

Modem to DTE

DM_A

DM_A

19

Request to Send B / Ready for Receiving B

DTE to Modem

RS B

RS B

7 Signal Ground

-

SG

SG

AB

102

20

Not used

8 Receiver Ready A

Modem to DTE

RR A

RLSD *

CF

109

21

Not used

9 Receive Clock B

Modem to DTE

RT B

SCR B

-

115

22

DCE Ready B

Modem to DTE

DM_B

DM_B

10 Receiver Ready B

Modem to DTE

RR

B

-

109

23

Not Used

11 Transmit Clock B

DTE to Modem

TT B

SCTE B

-

113

24

Transmit Clock A

DTE to Modem

TT A

SCTE A

DA

113

12 Internal Transmit Clock B

Modem to DTE

ST B

SCT B

-

114

25

Not Used

13 Not used

Notes:

1. Receiver-Ready is an EIA-232-level control signal on a V.35 interface.

2. 'B' signal lines are not used for EIA-232 applications.

3.

For X.21 operation, use the EIA-422 pins, but ignore Receive Clock if the modem is DTE, and ignore

Transmit clocks if the modem is DCE.

Advertising