B.3 crs-500 dsu tmi user data connectors – Comtech EF Data CRS-500 User Manual
Page 204

CRS-500 1:N Redundancy System
Revision 2
Appendix B
MN-CRS500
B–6
B.3
CRS-500 DSU TMI User Data Connectors
B.3.1 CRS-316 TMI – EIA-422/530, V.35, Sync EIA-232 Connector (DB-25F)
This “J2” DB-25F connector provides the EIA-232/422/V.35 User Data Interface on the CRS-316 TMI.
Table B-4. “J2” EIA-422/530 / V.35 / Sync EIA-232 User Data Connector
Pin #
Generic Signal Description
Direction
EIA-422/EIA-530
V.35
EIA-232
Circuit No.
1 Shield
-
Shield
FG
AA
101
14
Transmit Data B
DTE to Modem
SD B
SD B
-
103
2 Transmit Data A
DTE to Modem
SD A
SD A
BA
103
15
Internal Transmit Clock A
Modem to DTE
ST A
SCT A
DB
114
3 Receive Data A
Modem to DTE
RD A
RD A
BB
104
16
Receive Data B
Modem to DTE
RD B
RD B
-
104
4 Request to Send A / Ready for Receiving A
DTE to Modem
RS A
RS A
17
Receive Clock A
Modem to DTE
RT A
SCR A
DD
115
5 Not used
18
Not used
6 DCE Ready A
Modem to DTE
DM_A
DM_A
19
Request to Send B / Ready for Receiving B
DTE to Modem
RS B
RS B
7 Signal Ground
-
SG
SG
AB
102
20
Not used
8 Receiver Ready A
Modem to DTE
RR A
RLSD *
CF
109
21
Not used
9 Receive Clock B
Modem to DTE
RT B
SCR B
-
115
22
DCE Ready B
Modem to DTE
DM_B
DM_B
10 Receiver Ready B
Modem to DTE
RR
B
-
109
23
Not Used
11 Transmit Clock B
DTE to Modem
TT B
SCTE B
-
113
24
Transmit Clock A
DTE to Modem
TT A
SCTE A
DA
113
12 Internal Transmit Clock B
Modem to DTE
ST B
SCT B
-
114
25
Not Used
13 Not used
Notes:
1. Receiver-Ready is an EIA-232-level control signal on a V.35 interface.
2. 'B' signal lines are not used for EIA-232 applications.
3.
For X.21 operation, use the EIA-422 pins, but ignore Receive Clock if the modem is DTE, and ignore
Transmit clocks if the modem is DCE.