8 backup mode 2 select, 1 programming steps – Comtech EF Data RCS20 User Manual

Page 48

Advertising
background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–14

Key

Label

Function

S4

RETURN Pressed to return to the Backup Mode Configuration Screen.

Numeric Keypad ---

Press <CLR> or <RETURN> to abort programming (no switch parameters changed).
Returns to the Backup Mode Configuration Screen.

4.3.1.8 BACKUP MODE 2 SELECT

This screen allows the user to select the mode of backup operation for Backup Channel 2 (Prime Channel
9), if this channel is configured as a backup channel. The following backup modes are available:

Manual - allows the operator to force backups to occur even if prime channel modems have not
failed.

Non-Revertive - allows automatic backups to occur when prime channels fail, but once a channel
is backed up, it will remain backed up until manually reset by the operator.

Revertive - allows automatic backups to occur when prime channels fail, and after a channel is
backed up, if the prime channel clears its error, the backup can become available for another
prime channel.

4.3.1.8.1 Programming steps:

1. Press <MANUAL> to configure Backup Channel 2 for manual operation. The switch parameter

table will be updated immediately.

2. Press <NON-REV> to configure Backup Channel 2 for automatic non-revertive operation. The

switch parameter table will be updated immediately.

3. Press <REVERT> to configure Backup Channel 2 for automatic revertive operation. The switch

parameter table will be updated immediately.

4. Press <CLR> or <RETURN> to abort programming (no switch parameters changed). The display

will return to Config Switch Screen 4 (Backup Mode Configuration).

<BACKUP> MODE CONFIGURATION

BACKUP 2 <BACKUP> MODE: MANUAL

<MANUAL> <NON-REV> <REVERT> <RETURN>

Advertising