26 rdm fallback configuration, 1 programming steps – Comtech EF Data RCS20 User Manual

Page 85

Advertising
background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–51

4.3.2.26 RDM FALLBACK CONFIGURATION

This screen allows the user to configure the RDM Internal Reference Frequency. The internal frequencies
may be one of the following:

MHz

MHz

MHz

10.0 MHz

4.3.2.26.1 Programming steps:

1.

Press <TOG MODE> to change the displayed internal frequency.

2.

Continue pressing <TOG MODE> until the desired frequency is displayed.

3.

Press <CLR> or <RETURN> to abort programming (no switch parameters changed).

4.

Press <ENT> to load the information on the screen into the switch parameter table.

Key

Label

Function

S1

TOG
MODE

Press to cycle through the above listed internal frequencies.

S2

---

N/A

S3

---

N/A

S4

RETURN

Press to cycle back to the REFERENCE DISTRIBUTION CONFIGURATION
Screen.

Numeric Keypad ---

Press <CLR> or <RETURN> to abort programming (no switch parameters
changed).
Press <ENT> to load the information on the screen into the switch parameter table.

RDM INTERNAL REFERENCE CONFIGURATION

INTERNAL FREQ : 10.0 MHZ

TOG MODE RETURN