23 force manual backup 1, 1 programming steps – Comtech EF Data RCS20 User Manual

Page 62

Advertising
background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–28

4. Press <ENT> to load the information on the screen into the switch parameter table. Switching will

occur immediately after pressing <ENT>.

IMPORTANT
SET BU2 will be unavailable if Channel 9 is configured as a prime channel.

Key

Label

Function

S1

SET
BU1

Selects Backup Unit 1 for change and cycles to the FORCE MANUAL BACKUP 1
Subscreen.

S2

SET
BU2

Selects Backup Unit 2 for change and cycles to the FORCE MANUAL BACKUP 2
Subscreen.

S3

---

N/A

S4

NEXT

Press to cycle to the next screen.

Numeric Keypad ---

Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
Press <ENT> to load the information on the screen into the switch parameter table.
Switching will occur immediately after pressing <ENT>.

4.3.1.23 FORCE MANUAL BACKUP 1

This subscreen allows the user to switch prime channels to backup Channel 1 manually. Backup Channel
1 must be in manual mode for to force prime channels into backup. If a prime channel is configured for
linked switching, then switching the prime channel modulator only will also switch the demodulator.

4.3.1.23.1 Programming steps:

1. Press <MOD> or <DEMOD> to move the blinking cursor to the modulator or demodulator

selection.

2. Use the numeric keypad to enter the prime channel number to switch to Backup Channel 1.
3. Press <CLR> or <NEXT> to abort programming (no switch parameters changed).

FORCE <MANUAL> <BACKUP> 1

FORCE <BACKUP> 1 -> MODULATOR: 0

FORCE <BACKUP> 1 -> DEMODULATOR: 0

ENTER MOD ONLY FOR MODEM TYPE SWITCHING

MOD DEMOD RETURN