13 set date, 1 programming steps – Comtech EF Data RCS20 User Manual

Page 75

Advertising
background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–41

2.

Press <TIME> to cycle to the SET TIME Subscreen.

Key

Label

Function

S1

DATE Press to cycle to the SET DATE Subscreen.

S2

TIME Press to cycle to the SET TIME Subscreen.

S3

---

N/A

S4

NEXT Press to cycle to the next screen.

Numeric Keypad ---

N/A

4.3.2.13 SET DATE

This subscreen allows the user to configure the real-time clock date for the RCS20.

4.3.2.13.1 Programming steps:

1.

Press  or  to move the blinking cursor to the day, month, or year.

2.

Press <UP> to increase the value of the day, month or year (at the location of the blinking
cursor), press <DOWN> to decrease the value of the day, month, or year (at the location of the
blinking cursor).

3.

Press <CLR> to abort programming (no switch parameters changed).

4.

Press <ENT> to load the information on the screen into the switch parameter table.

Key

Label

Function

S1

Press to move the blinking cursor to the left. Used to select Year, Month, and/or Day to
be changed.

S2

Press to move the blinking cursor to the right. Used to select Day, Month, and/or Year to
be changed.

S3

UP

Press to increment the selected field.

S4

DOWN Press to decrement the selected field.

Numeric Keypad ---

Press <CLR> to abort changes and cycle back to the TIME / DATE CONFIGURATION
Screen.
Press <ENT> to accept the selected date.

SET DATE

DATE : 01 JAN 04

<--- ---> UP DOWN

Advertising