24 force manual backup 2, 1 programming steps – Comtech EF Data RCS20 User Manual

Page 63

Advertising
background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–29

4. Press <ENT> to load the information on the screen into the switch parameter table. Switching will

occur immediately after pressing <ENT>.

Key

Label

Function

S1

MOD

Press to place the blinking cursor on MODULATOR.

S2

DEMOD Press to place the blinking cursor on DEMODULATOR.

S3

---

N/A

S4

RETURN Press to return to the AUTO MODE BACKUP ASSIGNMENT SUMMARY Screen.

Numeric Keypad ---

Used to enter the prime channel number to switch to Backup Channel 1.
Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
Press <ENT> to load the information on the screen into the switch parameter table.
Switching will occur immediately after pressing <ENT>.

4.3.1.24 FORCE MANUAL BACKUP 2

This subscreen allows the user to switch prime channels to backup Channel 2 manually. Channel 9 must
be configured as Backup Channel 2, and Backup Channel 2 must be in manual mode to force prime
channels into backup. If a prime channel is configured for linked switching, then switching the prime
channel modulator only will also switch the demodulator.

4.3.1.24.1 Programming steps:

1. Press <MOD> or <DEMOD> to move the blinking cursor to the modulator or demodulator

selection.

2. Use the numeric keypad to enter the prime channel number to switch to Backup Channel 2.
3. Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
4. Press <ENT> to load the information on the screen into the switch parameter table. Switching will

occur immediately after pressing <ENT>.

Key

Label

Function

S1

MOD

Press to place the blinking cursor on MODULATOR.

S2

DEMOD Press to place the blinking cursor on DEMODULATOR.

FORCE <MANUAL> <BACKUP> 2

FORCE <BACKUP> 2 -> MODULATOR: 0

FORCE <BACKUP> 2 -> DEMODULATOR: 0

ENTER MOD ONLY FOR MODEM TYPE SWITCHING

MOD DEMOD RETURN