Page 46 of 61

p) If a rigid coupling is installed between the thrust

bearing and the sealing device, remove bolting of
the coupling spacer. Turn rotor adjusting nut
enough to remove rigid coupling spacer. Remove
the spacer.

q) Turn rotor adjusting nut until rotor rest on bottom

suction case.

r) Disconnect suction piping (if present on the

pump) and the discharge piping.

s) Lifting of short set pumps:

Refer back to section 2.3.

 Remove bolts that secure pumps to support

beam or foundation

 Attach a sling to pump lifting hooks and the

lift the pump vertically

 If present, unbolt and move aside pump

support beams

 Draw the entire pumping unit out of the

foundation opening

 Position pump horizontally on suitable

supports for disassembly in a safe and clean
area

 Refer to the following dismantling instruction

t) Lifting of deep set pumps:

 Remove bolts that secure pumps to support

beam or foundation

 If installed, remove the rigid coupling spacer

 If installed, remove the thrust bearing

assembly with the motor stool

 Remove the coupling hubs

 Remove stuffing box and Mechanical seal (or

packing seal) completely. Protect the shaft
against damage while lifting the discharge
head

 Lift the pump just enough to access the first

column pipe flange connection. Refer back to
section 2.3.4

 Support the entire pump just below the first

column pipe joint

 Disconnect the discharge head and lift. Refer

back to section 2.3.1

 Now lift the pump again by using column pipe

flange and disconnect the first section of
column piping

 Remove shaft couplings and repeat the

process until all column piping is
disassembled

 Last step is to lift and remove the bowl

assembly. Refer back to section 2.3.2

6.7.2 Pump dismantling instructions
If the pump has dismantled fully assembled, proceed
as follow:

a) If installed, unbolt and remove complete thrust

bearing assembly . At this point if it's desirable to
dismantle the bearing assembly, proceed as
follow:

 Remove rotor adjusting nut and key

 Remove thrust bearing fan security grid and

cooling fan

 Remove thrust bearing cover deflector.

Unscrew grub screws first.

 Unbolt and remove cover form thrust bearing

housing

 Remove spring and shaft guide sleeve

complete with line bearing, locking nut and
thrust bearing

 Unscrew locking nut and pull out thrust

bearing

 Pull out line bearing

b) If not done previously, remove bolts that secure

motor stool to pump head. Remove motor stool.

c) Remove the pump rigid coupling hub from the

pump shaft and its key.
If a mechanical seal is installed, remove the
mechanical seal cartridge.

For details on the dismantling of the

mechanical seal cartridge refer to the seal
manufacturer manual.
If the pump is equipped with packing seal,
remove the packing rings.

d) Remove

the

stuffing

box.

e) Disconnect pump head from top column pipe.
f) Slip pump head off top shaft.
g) Disconnect top column pipe and remove it from

top shaft.

h) Disconnect top shaft from lineshaft proceeding as

follow:

 Remove shaft coupling retaining spirolox ring

 Slide shaft coupling back and remove split

collar

i) Repeat above steps to disconnect all

intermediate column pipes and shafting until case
assembly is reached


6.7.3 Hydraulic section dismantling instructions
Disassembly the case assembly as follow:
a) Disconnect

lower

suction

case

b) Withdraw form casing pump shaft with impeller.
c) Remove impeller locking nut
d) Remove impeller and key

Advertising