Flowserve QLQ Vertical Worthington User Manual

Page 51

Advertising
background image

QLQ, QLQC USER INSTRUCTIONS ENGLISH 87900027 – 06/14

Page 51 of 61

d) Slide back coupling and install the retaining ring.
e) Fit the O-ring in place, install and bolt column to

its correspondent flange.

f) Repeat above steps to install the complete

shafting and all columns.

6.9.3 Pump completion

a) Fit O-ring in place, install and bolt discharge head

to top column.

b) Fit O-ring in place, install and bolt stuffing box to

discharge head.

c) If the pump is provided with packing seal,

assemble packing. If the pump is provided with
mechanical seal, install mechanical seal cartridge
and bolt seal end plate in position.

At this stage do not lock

mechanical seal sleeve to pump shaft and do not
remove locking tabs.

d) If rigid coupling is provided, install rigid coupling

key, half coupling, coupling nut and coupling nut
screws. Align the coupling hubs with a max
tolerance of 0.025 mm (0.001 in).

e) If provided, install rigid coupling spacer.
f) Push pump shaft until rotor rests on lower suction

case.

g) Install

motor

stool.

h) If provided, install complete thrust bearing

assembly with rigid half coupling in place. Bolt
rigid coupling spacer. If no rigid coupling is
provided, install the bearing house directly on the
shaft.

i) If flexible coupling is provided, install flexible

coupling key and pump half coupling. Pre-heat
coupling hub to approx. 150 °C (300°F).

6.9.4 Pump re-installation
a) Lift pump vertically and lower it down into

foundation opening. Refer back to section 2.3.

b) Secure pumps discharge head to foundation

plate or discharge beams, whichever is provided.

c) For pump in can, secure pump discharge head to

can flange.

d) Bolt pump nozzle(s) to discharge ( and suction- in

case of pump in can) piping.

e) Set the driver as described under Chapter 4 of

this manual.

f) Check driver/driven shaft alignment and

assemble the coupling between the two shafts.

g) Position pump shaft axially acting on adjusting

nut so that space between coupling halves is as
specified on pump elevation drawing.

h) Screw adjusting nut locking screws.
i) If the pump id provided with mechanical seal,

lock mechanical seal sleeve to pump shaft and
remove locking tabs.

j) Replace all auxiliary piping, systems,

instrumentation and pipe plugs.

k) If the pump has a thrust bearing in the pump,

install oilier and fill thrust bearing house to correct
oil level (refer to section 5.3).

l) Install

coupling

guards.

m) Refer to Chapter 5 for commissioning and

starting procedure.