Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June

04

Page 13 of 68

Store pumping unit

NOTE

The following description refers to
pumps without auxiliary carriers.

Should the pump be delivered on an
auxiliary carrier, refer to the pump
manual for storage and shipping
instructions
.

Store the pumping unit as follows:

Motor:

Preferably vertically

Filled with oil

Pump bowl assembly with rubber bearing
bushes:

Vertically

Pump bowl assembly with other than rubber
bearing bushes:

Preferably

vertically

DANGER

Horizontally stored motors and
pump bowl assemblies must be se-
cured against rolling.

Vertically stored motors and pump
bowl assemblies must be secured
by appropriate means in this stor-
age position to prevent tipping over.

Power cable:

Leads protected from moisture

NOTE

Do not bend power cable during
storage.

Maintenance during storage

Storage up to four weeks

At the beginning and end of the storage pe-
riod: Carefully check the motor to be sure
there are no signs of oil leakage.

Storage between 1 and 24 months

Maintenance of the motor, every 6 to 8 weeks:

1. Remove the motor shipping cap (112) at

the motor.

2. Turn the motor shaft several times by

means of a wrench.

3. Mount the motor shipping cap (112) to

the motor.

Maintenance of the pump, every 6 to 8 weeks:

1. Remove the discharge housing and the

non-return valve for the pump shaft.

2. Turn the pump shaft several times by

means of a wrench.

4. Mount the discharge housing and non-

return-valve to the pump.

Storage for over 24 months

After a storage of more than 24 months, we
recommend a complete visual inspection at
our main factory or at your nearest Flowserve
representative.

Shipping

Ship motor and pump bowl assembly

in non-airtight protection film

in wooden box or similar transport packaging.

2.4 Recycling and end of product life

At the end of the service life of the pumping unit or
its parts, the relevant materials and parts should be
recycled or disposed of using an environmentally
acceptable method and heeding local regulations.

If the product contains substances which are harm-
ful to the environment, these should be removed
and disposed of in accordance with local regula-
tions. This also includes the liquids and or gases in
the "seal system" or other utilities.

DANGER

Make sure that hazardous sub-
stances are disposed of safely and
that the correct personal protective
equipment is used.

The safety specifications must be in
accordance with the local regula-
tions at all times.

Hazardous substances in the pumping unit are

Motor oil

Advertising