Page 57 of 68 – Flowserve Byron Jackson Type M User Manual

Page 57

Advertising
background image

®

Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June

04

Page 57 of 68

FAULT SYMPTOM

Motor protection triggered

⇓ Pump does not start

⇓ Flow inadequate

⇓ Pumping unit runs, but does not pump

⇓ Shut-off head current (amps) is higher than originally recorded but shut-off head is not diminished

⇓ Shut-off head is diminished but shut-off current (amps) is unchanged

⇓ Shut-off head is diminished and shut-off current (amps) is much higher

⇓ Duty capacity and head are low but running current (amps) and shut-off valves are normal

⇓ Pump starts bus trips circuit breaker

⇓ Pump does not start

PROBABLE CAUSES

POSSIBLE REMEDIES

A. SYSTEM TROUBLES

z Pump

or

motor

sluggish

Check

smooth

running

of

pump

and

motor.

z

Heat to great because total system head does
not correspond to pump characteristics.

Reduce head.

z

Unit not suspended in pumping medium due to
inadequate installation depth.

Check well level and/or suspend unit
deeper.

B. MECHANICAL TROUBLES

z

Pump blocked due to impurities in the pump.

Disassemble pump section and clean.

z Reduction

of

area

in

the

pressure

pipe

be-

cause isolator valves are not completely open.

Completely open isolator valves.

z Reduction

of

area

in

the

pressure

pipe

be-

cause pressure pipe is clogged.

Clean pressure pipe.

z Reduction

of

area

in

the

pressure

pipe

be-

cause of foreign body in the pipe.

Clean pipework.

z Reduction

of

area

in

the

pressure

pipe

be-

cause well filter stopped up.

Remove unit and regenerate well.

z Pressure

pipe

leak

due

to

defective

pipework. Check

pipework.

z Impellers

worn

out

because

of

high

sand

con-

tent in the pumping medium.

Remove pump and repair.

Check material selection.

Analyze water.

z Impellers

worn

out

because

of

corrosive

pump-

ing medium

Remove pump and repair.

Check material selection.

Analyze water.

z Impellers

worn

out

because

of cavitation.

Check operating conditions.

z Pressure

pipe

not

free

because

main

slide

valve is closed.

Check blockage and control units.

z Motor runs but pump does not turn because

coupling between pump and motor is defective.

Remove unit and repair.

z Suction

sieve

stopped

up

because

of

foreign

body in well

Remove unit and clean suction sieve..

z Fracture

in

riser

pipe

Replace respective riser pipe

z

Valve open on by-pass line etc.

Close respective valve