4.1 Fitter

It is recommended that the services of Flowserve
be employed for the installation and initial starting
of a Byron Jackson pump.

Such service will ensure the purchaser that the
equipment is properly installed, and will provide an
excellent opportunity for the plant operator to re-
ceive special instructions relative to the pumping
unit.

4.2 Equipment and personnel re-

quired

4.2.1

Equipment and tools supplied with mo-
tor

Equipment and tools supplied with motor and
half coupling

Hex socket wrench for shaft button screw
(806-2)

Hex socket wrench for coupling set screw
(806-1)

Hex socket wrench for vent plug (806-4)

Hex socket wrench for vent plug (806-5)

Aligning jig assembly, including the following
parts:

-

Shim, shaft adjusting (262-6)

-

Shim, shaft adjusting (262-7)

-

Button, thrust (130)

-

Screw, thrust Button (806-2)

-

Washer, coupling lock screw (690-4)

-

Screw, coupling lock (806-3)

-

Aligning jig (265)

-

Coupling, driver (529)

-

Key, coupling (676-1)

-

Screw, set, coupling (806-1)

4.2.2

Equipment and tools to be supplied by
operator

Provide the following equipment and tools:

Lifting Equipment.

Must be of sufficient strength and rigidity to lift
the complete unit safely, see Table 3,
Page 20, an
d of sufficient height to allow
clearance between load hook and foundation.
For weight see Chapter 12.2 "Data sheet".

Two pairs of correctly sized pipe elevators

One correctly sized column U-plate

One correctly sized motor U-plate (see Figure
5, Page 21 and Table 4, Page 21)

One 1.2 - 1.8 m (4 - 6 feet) section of column,
threaded and coupled, to be attached to the
top case and used for handling the pump bowl
assembly.

Deduct this length from total column length
specifications.

Column

A supply of pipe, in random lengths, threaded
and coupled, of correct size to handle the unit
capacity and total weight and of adequate
length to set the unit at the correct pumping
level in the well. The threading is 8 threads
per 25 mm (1 inch) and 19 mm (0.75 inch) ta-
per per foot.

One pair of cable reel stands, with axle

One portable insulation resistance tester
("Megger"), 0 - 100 M

Ω / 1000 Volts

One clamp-on ammeter

One volt/ohmmeter

Components for water level indicating system

Special banding tool ("Band-it") for cable
bands

A length of 1.27 cm (0.5 inch) hemp rope and
a cable installation wheel. Diameter must be
at least 14 times cable outer diameter.

Ordinary hand tools (mechanical and electri-
cal) used in this kind of work

Two sets of chain tongs

Rubber mat and insulated gloves for electrical
work in damp conditions